title: Upgrade firmware Ingics Beacon Gateway iGS03W, iGS03M
description: "Check Firmware version - Access your webpage or Beacon Gateway - Login to Beacon Gateway - Click on  SYSTEM mene Upgrade Firmware Upgrade by OTA method - enc file (for firmware version v1.0.9.0) Open CMD or Terminal Access the Beacon…"
url: "https://colliebots.com/docs/collie/upgrade-firmware-ingics-beacon-gateway-igs03w-igs03m/"
updated: "2024-09-30"
category: Collie
---

# Upgrade firmware Ingics Beacon Gateway iGS03W, iGS03M

Check Firmware version

- Access your webpage or Beacon Gateway
- Login to Beacon Gateway
- Click on  SYSTEM mene

Upgrade Firmware

 Upgrade by OTA method - enc file (for firmware version v1.0.9.0)
  Open CMD or Terminal Access the Beacon Gateway using Telnet (telnet gateway-ip) Paste the fullowing commad

- SYS WORKMODE 0
- REBOOT

  Connect to Gateway again and paste this command

- SYS OTA RES [https://ingics.ddns.net:9999/ota/igs03/v1.1/igs03-res-v1.1.9.2.enc](https://ingics.ddns.net:9999/ota/igs03/v1.1/igs03-res-v1.1.9.2.enc)
- SYS OTA APP [https://ingics.ddns.net:9999/ota/igs03/v1.1/igs03-app-v1.1.9.2.enc](https://ingics.ddns.net:9999/ota/igs03/v1.1/igs03-app-v1.1.9.2.enc)
- SYS OTA START

     Once OTA is done, Change back to mqtt mode

- SYS WORKMODE 3
- REBOOT

   Check the firmware version after the update. You can view the version by accessing the Beacon Gateway webpage - SYSTEMS menu, or through Telnet using the 'SYS INFO' command.  ---------------------  Upgrade using the OTA method - bin file (for firmware versions below v1.0.9.0)    Open CMD or Terminal Access the Beacon Gateway using Telnet (telnet gateway-ip) Paste the fullowing commad

- SYS WORKMODE 0
- REBOOT

  Connect to Gateway again and paste this command

- SYS OTA RES [https://ingics.ddns.net:9999/ota/igs03/v1.1/igs03-res-v1.1.9.2.bin](https://ingics.ddns.net:9999/ota/igs03/v1.1/igs03-res-v1.1.9.2.bin)
- SYS OTA APP [https://ingics.ddns.net:9999/ota/igs03/v1.1/igs03-app-v1.1.9.2.bin](https://ingics.ddns.net:9999/ota/igs03/v1.1/igs03-app-v1.1.9.2.bin)
- SYS OTA START

     Once OTA is done, Change back to mqtt mode

- SYS WORKMODE 3
- REBOOT

   Check the firmware version after the update. You can view the version by accessing the Beacon Gateway webpage - SYSTEMS menu, or through Telnet using the 'SYS INFO' command.